U.S. Smoke & Fire Hose Stream 180 Steel-tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 3 hour fire protection rating and therefore can be used in a two hour fire rated wall assembly.

Please see below the IBC TABLE OPENING FIRE PROTECTION ASSEMBLIES

Table 715.3 Fire Door and Fire Shutter Fire Protection Ratings


3 Hour Fire Barrier Enclosing Wall per IBC TableKey Features

  • 3-Hour Fire Protection -- The Hose Stream 180 Fire Shutter meets UL 10B standards and is rated for a minimum of 3-hour fire protection, making it suitable for 2-hour fire-rated wall assemblies.
  • IBC Code Compliance -- Designed to comply with International Building Code (IBC) requirements for opening protective assemblies.
  • Hose Stream Tested -- Successfully passed the ASTM E2226 hose stream test, ensuring durability under fire conditions.
  • Automated Operation -- Releases upon receiving a fire alarm signal, with push-to-exit buttons for egress and optional safety sensors.
  • Multibarrel Design -- Features a Steel-Tex fabric overlap (24") with an inverted T bottom bar for stability, allowing safe passage during emergencies.
  • Easy Installation -- Mounted with threaded rods and unistruts, requiring a 120V power supply to the motor side of the headbox.

It is crucial to adhere to building codes when installing fire shutters to ensure compliance and maximize safety.

The U.S. Smoke & Fire Hose Stream 180 shutter is tested to UL 10B and has a minimum of 3 hour fire protection rating to be sufficient for an opening protective in a 3-hour fire barrier enclosing wall per IBC Table. A hose stream test (ASTM E2226) is conducted as part of the fire endurance testing and the shutter shall have passed this test.

The head-box is mounted utilizing threaded rods and unistruts. For power, 120V to motor side of the head-box. The Steel-Tex Fire Shutter (SFS) will release when receiving a signal from fire alarm system (FAS). Push to exit buttons are installed for egress. Leading edge safety sensor option. BMS relay option. Beam Sensor option.

Fire doors also play a critical role in fire protection by containing flames and smoke during a fire.

The Hose Stream 180 is a multibarrel assembly with steel-tex fabric overlap of 24". A building occupant can step through the overlap to the opposing side of the shutter. The inverted T bottom bar holds the overlap in place for the length of the headbox. 

 

Product Downloads For HOSE STREAM 180:

Multi-Level Atriums: Smoke & Fire Curtain Applications
Smoke curtains reduce the make-up air requirements and channel and...
Learn More
Museum Applications for Smoke & Fire Curtain Systems
Museums constructed in the last 50 years have drifted away...
Learn More
Metro Stations: Smoke & Fire Curtain Applications
Metro Stations are mission critical facilities that must continue operation...
Learn More
Escalators & Stairs: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications for Escalators & Stairs is a...
Learn More
Historic Buildings: Smoke & Fire Curtain Applications
Whether it is the renovation of Montpelier, or the updating of...
Learn More
Prison & Detention Centers: Applications of Smoke & Fire Curtains
Prisons and detention facilities are a particularly daunting design...
Learn More
Airports Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications in Airports are a...
Learn More
High Rise Hotels & Condominiums: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications Provide Added Safety for High...
Learn More
Terrorist Threat Fire Protection with Smoke & Fire Curtain Applications
Mission critical structures, such as ports, nerve centers, power...
Learn More
Elevators: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications in Elevators Play an Important...
Learn More
Stages & Auditoriums: Smoke & Fire Curtain Applications
Our smoke curtains are readily applied to the needs of custom-made...
Learn More

The UL trademark is a registered trademark of Underwriters Laboratories.

866-204-8640