Make U.S. Smoke & Fire your Basis of Design
UL Listed, UL Labeled, UL Certified, UL Recognized Fire protective smoke curtains (File# R26410)

High Rise Hotels & Condominiums: Smoke & Fire Curtain Applications

Smoke & Fire Curtain Applications Provide Added Safety for High Rises

A smoke curtain installed inside the entrance doorway to a condominium or hotel room will give 2 hours of additional protection to the threat posed by fire and smoke. When residents or guests are trapped in their room, particularly on upper floors, smoke seepage can be a true threat, especially for children and elders. Historically residents or guests have been forced to protect themselves by placing towels under their doors.

A fire and smoke curtain can be manually or automatically (we can integrate with your home security and/or fire alarm system) dropped from the ceiling, behind the entrance doorway, and will minimize the smoke seeping under the door threshold and enhance survivability. If escape is possible, the deployment of a fire and smoke curtain after departure can substantially reduce damage to the contents of a condominium or hotel room.

We at U.S. Smoke & Fire believe that smoke curtain technology can substantially improve your sense of security, and help protect your life and your belongings.

View Additional Applications Below:

Why Choose Fire Protective Smoke Curtains for Your Open Floor Plan?
  • Rated as for 1 hour, 2 hours and 3 hour smoke and fire partition, barrier and opening protective.
  • Only a 7 inch by 7 inch housing for up to a 18 feet length with a 10 feet drop height.
  • Housings of 7 inch by 11 inches for lengths longer than 19 feet.
  • Typical 60 feet length curtain housing with 40 foot drop only 8 inches by 13 inches.
  • Accordion smoke and fire barrier systems makes turns and angles without posts and rails.
  • Gravity Fail Safe Deployment.
  • Fully Integrates with Fire Alarm System with optional building management system relay per UL 864.
  • Report holder for Elevator smoke containment and elevator lobby smoke containment per ICC AC-77.
  • Utilized to Rate Corridor in lieu of fire rated glass, washing glass In lieu of horizontal accordion doors and cross corridor area separation with pass through egress.
  • Enclose monumental stairways and secondary Egress paths makes fixed glass draft curtains a thing of the past.
  • Curtains with redundant forms of egress, pass through egress, rewind switches, two stage descents, delayed descents.
  • Curtains used for stages per NFPA 80 guidelines.
  • Restricts Atrium Volume as part of an Atrium Smoke Management System per IBC 909 and IBC 404.5 exception 3.
  • Provides Atrium Separation per IBC 404.5 Exception 6 back to 2 floor rule for removal of smoke management system.
  • Horizontal Curtains to separate two floors allows architects to design more open floor plans.
It's not just what we make,
it's what we make possible.