Make U.S. Smoke & Fire your Basis of Design
UL Listed, UL Labeled, UL Certified, UL Recognized Fire protective smoke curtains (File# R26410)

Hose Stream 180

U.S. Smoke & Fire Hose Stream 180 Steel-tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 3 hour fire protection rating and therefore can be used in a two hour fire rated wall assembly.

Please see below the IBC TABLE OPENING FIRE PROTECTION ASSEMBLIES

Table 715.3 Fire Door and Fire Shutter Fire Protection Ratings


3 Hour Fire Barrier Enclosing Wall per IBC TableKey Features

  • 3-Hour Fire Protection -- The Hose Stream 180 Fire Shutter meets UL 10B standards and is rated for a minimum of 3-hour fire protection, making it suitable for 2-hour fire-rated wall assemblies.
  • IBC Code Compliance -- Designed to comply with International Building Code (IBC) requirements for opening protective assemblies.
  • Hose Stream Tested -- Successfully passed the ASTM E2226 hose stream test, ensuring durability under fire conditions.
  • Automated Operation -- Releases upon receiving a fire alarm signal, with push-to-exit buttons for egress and optional safety sensors.
  • Multibarrel Design -- Features a Steel-Tex fabric overlap (24") with an inverted T bottom bar for stability, allowing safe passage during emergencies.
  • Easy Installation -- Mounted with threaded rods and unistruts, requiring a 120V power supply to the motor side of the headbox.

It is crucial to adhere to building codes when installing fire shutters to ensure compliance and maximize safety.

The U.S. Smoke & Fire Hose Stream 180 shutter is tested to UL 10B and has a minimum of 3 hour fire protection rating to be sufficient for an opening protective in a 3-hour fire barrier enclosing wall per IBC Table. A hose stream test (ASTM E2226) is conducted as part of the fire endurance testing and the shutter shall have passed this test.

The head-box is mounted utilizing threaded rods and unistruts. For power, 120V to motor side of the head-box. The Steel-Tex Fire Shutter (SFS) will release when receiving a signal from fire alarm system (FAS). Push to exit buttons are installed for egress. Leading edge safety sensor option. BMS relay option. Beam Sensor option.

Fire doors also play a critical role in fire protection by containing flames and smoke during a fire.

The Hose Stream 180 is a multibarrel assembly with steel-tex fabric overlap of 24". A building occupant can step through the overlap to the opposing side of the shutter. The inverted T bottom bar holds the overlap in place for the length of the headbox. 

 

Product Downloads For HOSE STREAM 180:

Why Choose Fire Protective Smoke Curtains for Your Open Floor Plan?
  • Rated as for 1 hour, 2 hours and 3 hour smoke and fire partition, barrier and opening protective.
  • Only a 7 inch by 7 inch housing for up to a 18 feet length with a 10 feet drop height.
  • Housings of 7 inch by 11 inches for lengths longer than 19 feet.
  • Typical 60 feet length curtain housing with 40 foot drop only 8 inches by 13 inches.
  • Accordion smoke and fire barrier systems makes turns and angles without posts and rails.
  • Gravity Fail Safe Deployment.
  • Fully Integrates with Fire Alarm System with optional building management system relay per UL 864.
  • Report holder for Elevator smoke containment and elevator lobby smoke containment per ICC AC-77.
  • Utilized to Rate Corridor in lieu of fire rated glass, washing glass In lieu of horizontal accordion doors and cross corridor area separation with pass through egress.
  • Enclose monumental stairways and secondary Egress paths makes fixed glass draft curtains a thing of the past.
  • Curtains with redundant forms of egress, pass through egress, rewind switches, two stage descents, delayed descents.
  • Curtains used for stages per NFPA 80 guidelines.
  • Restricts Atrium Volume as part of an Atrium Smoke Management System per IBC 909 and IBC 404.5 exception 3.
  • Provides Atrium Separation per IBC 404.5 Exception 6 back to 2 floor rule for removal of smoke management system.
  • Horizontal Curtains to separate two floors allows architects to design more open floor plans.