Applications
U.S. Smoke and Fire provides furnish and install subcontractor services nationally and internationally well into our second decade.
Request Information

HOSE STREAM 120- TESTED FOR 1 1/2 HOURS TO UL 10B STANDARD WITH HOSE STREAM TEST (ASTM E2226) FOR UP TO A 2 HOUR WALL

U.S. Smoke & Fire Hose Stream 120®  (SFS) is an opening protective that meets the requirement for a 90-minute fire protection rating and therefore can be used in a two hour fire rated wall assembly.

Please see below IBC TABLE OPENING FIRE PROTECTION ASSEMBLIES

The U.S. Smoke & Fire Hose Stream 120® is tested to UL 10B and has a minimum of 1 1/2 hour fire protection rating to be sufficient for an opening protective in a 2- hour fire barrier enclosing wall per IBC Table. A hose stream test (ASTM E2226) is conducted as part of the fire endurance testing and the shall have passed this test.

The head-box is mounted utilizing threaded rods and unistruts. For power, 120V to motor side of the head-box. The Steel-Tex Fire Shutter (SFS) will release when receiving a signal from the fire alarm system (FAS). Push to exit buttons are installed for egress. Leading edge safety sensor option. BMS relay option. Beam Sensor option.

Hose Stream 120® Installed Back to Back

Please note that two systems each with a fire protection rating of 1 1/2 hour, installed on opposing sides of the same opening in a fire wall, shall be deemed equivalent in fire protection rating to one 3-hour system per IBC table a.- Harmathy's Principle

Product Downloads For HOSE STREAM 120:

PRODUCT DOWNLOADS FOR HOSE STREAM 120® INSTALLED BACK TO BACK FOR 90 MINUTES EACH (3 HOURS BY HARMATHY PRINCIPLE)

Multi-Level Atriums: Smoke & Fire Curtain Applications
Smoke curtains reduce the make-up air requirements and channel and...
Learn More
Museum Applications for Smoke & Fire Curtain Systems
Museums constructed in the last 50 years have drifted away...
Learn More
Metro Stations: Smoke & Fire Curtain Applications
Metro Stations are mission critical facilities that must continue operation...
Learn More
Escalators & Stairs: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications for Escalators & Stairs is a...
Learn More
Historic Buildings: Smoke & Fire Curtain Applications
Whether it is the renovation of Montpelier, or the updating of...
Learn More
Prison & Detention Centers: Applications of Smoke & Fire Curtains
Prisons and detention facilities are a particularly daunting design...
Learn More
Airports Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications in Airports are a...
Learn More
High Rise Hotels & Condominiums: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications Provide Added Safety for High...
Learn More
Terrorist Threat Fire Protection with Smoke & Fire Curtain Applications
Mission critical structures, such as ports, nerve centers, power...
Learn More
Elevators: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications in Elevators Play an Important...
Learn More
Stages & Auditoriums: Smoke & Fire Curtain Applications
Our smoke curtains are readily applied to the needs of custom-made...
Learn More

The UL trademark is a registered trademark of Underwriters Laboratories.

866-204-8640