Applications
U.S. Smoke and Fire provides furnish and install subcontractor services nationally and internationally well into our second decade.
Request Information

SD240A Fire Protective Curtain

Applications:

  1. Openings in Smoke Barrier walls
  2. Openings in Fire Partition walls
  3. Enclosing monumental stairways with a fabric corner curtain at the 90-degree angle or an obtuse angle.
  4. No column required as accordion curtain fabric turns a corner.

Description:

SD240A® Fire Protective smoke curtains are considered "smoke barriers" in the IBC. The SD240A® will deploy to the floor. The SD240A® utilizes wall trays that are flush with the face of drywall.

Testing & Certification Agency Listings:

UL 10B -- 20 minutes (no hose) Intertek

UL 10D- 3 Hour- UL

UL 1784- Intertek

ASTM E84- Intertek

ASTM E136- NGC

International Building Code Test Relevant Information:

UL 10B 20-minutes has no hose stream test requirement

Technical Information:

  1. Robust Construction- Headbox manufactured 18-gauge steel, all glass textile with polyurethane coating- The complete assembly is listed which is the headbox, fabric, motor and bottom bar.
  2. Accessible Maintenance- Removable bottom cover plate of headbox at ceiling for access to the low voltage motor and fabric.
  3. Head Box Sizes- 12-inch by 12-inch headbox for single roller system up to 12-feet in length and 10-foot drop height (refer to headbox sizing chart) 9-inches by 9-inch headbox for single roller system up to 12-feet in length and 20-foot drop height.
  4. Wall Tray- Factory Etched Primed, 12-inches in width by 3-inches in depth
  5. Length and Drop Height Limits- Length 146 feet, Drop Height 20 feet
  6. UL 864 listed Battery Back Up- Standard 2 12-volt batteries in UL 864 listed Control Panel and Motor Controller typically 40-feet away from Curtain head box for 14-2 low voltage wiring, 12-2 low voltage wiring for 80-feet away from Curtain headbox.
  7. Control Panel -- connected directly to Addressable Fire Alarm system by closed contact that opens on fire signal from Smoke/IR detector. The contact type must be volt free, dry contact. Each Control Panel draws 7 amps. Control Panel requires 120 volts, typically a 20-amp circuit breaker. The circuit shall be a dedicated circuit marked life safety. Each control panel can control 4 motors. Each curtain roller utilizes 1 motor. If the curtain requires up to 8 motors, then a second Control Panel will be wired in series. If the curtain requires 12 motors, then a third Control Panel will be wired in series. Up to 9 Control Panels may be wired in series.
  8. Smoke Detector Activation- the Smoke/IR detector wiring can be wired directly to the Control panel if there is no central fire alarm system in the building.
  9. Egress- Egress options, are two stage descent where in stage 1 curtain dwell 6' 8" AFF for 1-minute then stage 2 curtain deploys to floor. Emergency Retract Button (EUB). Button is placed on wall up to 3 feet away from curtain at 36"- 42" AFF.
  10. Egress- There is no handicapped wheelchair egress. An integral swing door would be another model such as the Hose Stream 120® First Responder with Integral Swing door.
  11. Obstruction Sensor- Obstruction sensor option is a class 1 laser beam that is set next to bottom bar to annunciate after a period of 15-minutes to warn of an obstruction. This sensor can be connected to building management system (BMS relay) for monitoring.

FREQUENTLY ASKED QUESTIONS (FAQ):

Can I use the SD240A® for an opening in a fire wall or fire barrier?

No, openings in fire walls and fire barriers must be UL 10B with the hose stream test per IBC Table 716. This product category is tested to UL 10D which does not include the hose stream test. Thus, if the opening is a fire partition wall or smoke barrier wall, then the UL 10D listed system is appropriate. A UL 10D product tested to 20-minutes, 1-hour, 90-minutes, or 2-hours to UL 10D all default to UL 10B 20-minute (no hose).

Does the fabric come in various colors?

The fabric comes in gray only.

Does the headbox come in different colors?

Yes, Ral colors, white, gray, black standard and all other Ral Colors optional. USSF recommends factory-etched primed and paint in field so that the sheen will match better.

What is the drop speed of the curtain?

NFPA 80 Chapter 21 Fire Protective Curtains states that drop speed must be 6-inches to 24-inches per second.

Can I use my curtain to deploy and retract by a remote key switch, as I am using it to close off an area?

Yes, the curtain can be controlled by a remote key switch in view of the curtain to deploy and retract the curtain. There is an optional "door mode" software that will allow the user to deploy the curtain without any beeping of the control panel which would normally beep when the curtain is deployed.

Does the curtain automatically reset when the smoke/IR detector or fire alarm system reset to normal non-alert mode?

Yes, the system is automatic, once the closed contact from FAS opens, the curtain drops to its operational position and when the FAS contact closes, the curtain motors engage, and the curtain retracts back into its headbox.

VIEW IMAGES OF THE SMOKE CURTAIN IN ACTION:

Product Downloads:

SEE THE SMOKE CURTAIN IN ACTION:

View Additional Products Below:

Multi-Level Atriums: Smoke & Fire Curtain Applications
Smoke curtains reduce the make-up air requirements and channel and...
Learn More
Museum Applications for Smoke & Fire Curtain Systems
Museums constructed in the last 50 years have drifted away...
Learn More
Metro Stations: Smoke & Fire Curtain Applications
Metro Stations are mission critical facilities that must continue operation...
Learn More
Escalators & Stairs: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications for Escalators & Stairs is a...
Learn More
Historic Buildings: Smoke & Fire Curtain Applications
Whether it is the renovation of Montpelier, or the updating of...
Learn More
Prison & Detention Centers: Applications of Smoke & Fire Curtains
Prisons and detention facilities are a particularly daunting design...
Learn More
Airports Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications in Airports are a...
Learn More
High Rise Hotels & Condominiums: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications Provide Added Safety for High...
Learn More
Terrorist Threat Fire Protection with Smoke & Fire Curtain Applications
Mission critical structures, such as ports, nerve centers, power...
Learn More
Elevators: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications in Elevators Play an Important...
Learn More
Stages & Auditoriums: Smoke & Fire Curtain Applications
Our smoke curtains are readily applied to the needs of custom-made...
Learn More

The UL trademark is a registered trademark of Underwriters Laboratories.

866-204-8640