Hose Stream 120 Horizontal

TESTED FOR 120 MINUTES FIRE PROTECTION RATING WHEN TESTED IN ACCORDANCE WITH UL 10B STANDARD WITH HOSE STREAM TEST (ASTM E2226)

Hose Stream 120 Horizontal Fire Shutter 2
Hose Stream 120 Horizontal Fire Shutter is utilized to enclose a floor opening for continuity of rating. Designed with a winding track system for a rectangular or square shape. Maximum size is 20ft in width(headbox) x 40ft in length(side guides).
Tested for 120 minutes fire protection rating when tested in accordance with UL 10B standard with hose stream test (ASTM E2226).

TECHNICAL INFORMATION

  • 120 Minutes with accordance with UL10B
  • ASTM E2226 (Hose Stream Test) 2.5 Minute
  • Standard with battery back-up

 

Product Downloads For Hose Stream 120® Horizontal:

SD60GS Fire Protective Curtain
Applications: Openings in Smoke...
Learn More
SD240GS 2HR Fire Protective Curtain
Applications: Openings in Smoke...
Learn More
SD240GS Fire Protective Curtain with pass through slot
Applications: Openings in Smoke...
Learn More
SD240A Fire Protective Curtain
Applications: Openings in Smoke Barrier...
Learn More
HOSE STREAM 180 - TESTED FOR 3 HOURS TO UL10B STANDARD WITH HOSE STREAM TEST (ASTM E2226) FOR UP TO A 3 HOUR WALL
U.S. Smoke & Fire Hose Stream 180® Steel-Tex® Fire Shutter (SFS) is an opening protective that meets the requirement for a 3 hour fire protection rating and therefore can be used in a 3-hour fire wall or fire barrier wall assembly. Please...
Learn More
Dual Hose Stream 120
  U.S. SMOKE & FIRE DUAL HOSE STREAM 120 WHEN 25% OF THE OPENING IN A FIREWALL IS EXCEEDED THEN AN ASTM E119 (UL 263) LISTED AND LABELED ASSEMBLY IS REQUIRED IN COMPLIANCE WITH IBC SECTION 707.6 EXCEPTION 3. THE DUAL CURTAIN IS...
Learn More
Magnetic Seal Elevator Smoke Containment (ESC)
Applications: Elevator Hoist Way Smoke...
Learn More
Hose Stream 180 First Responder
U.S. Smoke & Fire Hose Stream 180® Steel-Tex® Fire Shutter (SFS) is an opening protective that meets the requirement for a 3 hour fire protection rating and therefore can be used in a 3-hour fire wall or fire barrier wall assembly. This...
Learn More
Hose Stream 120 Horizontal SR Sliding Retract Egress
Rendering Applications: Openings in Fire Walls, Fire Barriers, Fire partitions, Elevator Lobby Interface opening for sliding retract egress Openings in corridors with sliding retract egress ...
Learn More
Hose Stream 120 First Responder
U.S. Smoke & Fire Hose Stream 120 FIRST RESPONDER Steel-Tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 90- minute fire protection rating and therefore can be used in a two-hour fire rated wall or fire barrier...
Learn More
SD60GS Elevator Smoke Containment
Applications: Elevator Hoist way Smoke...
Learn More
SD60 Fixed Fabric Draft Curtain
Applications: Aircraft Hanger ...
Learn More
SD60 Deployable Draft Curtain
Applications: Monumental Stairway to replace glass smoke baffles Description: Deployable draft curtains are considered “smoke partitions” in the IBC. There is a requirement for a smoke...
Learn More
SD60 Smoke Curtain
Applications: Multi-level Atrium Smoke...
Learn More
HOSE STREAM 120- TESTED FOR 1 1/2 HOURS TO UL 10B STANDARD WITH HOSE STREAM TEST (ASTM E2226) FOR UP TO A 2 HOUR WALL
U.S. Smoke & Fire Hose Stream 120®  (SFS) is an opening protective that meets the requirement for a 90-minute fire protection rating and therefore can be used in a two hour fire rated wall assembly. Please see below IBC TABLE...
Learn More
Dual Hose Stream 120 SWR Sliding Wall Retract Egress
Applications: Openings in Fire Walls, Fire Barriers, Fire partitions, Elevator Lobby Interface opening for sliding retract egress Openings in corridors with sliding retract egress ...
Learn More

The UL trademark is a registered trademark of Underwriters Laboratories.

866-204-8640